DocumentMT0100P.N
©XsensTechnologiesB.V. MTiandMTxUserManualandTechnicalDocumentation
31
ThePreamble,BusID,MesssageID,lengthindicatorandchecksumtogetherisalways5bytes.Thelengthofthe
variousdatamessagesisdiscussedin[LLCP].
Example1:Calibrateddataoutputmodeat100Hzwithabaudrateof115200bps.
Calibrateddatais36bytes.
ms
sbits
bytebits
timeontransmissi 56.3
)/(115200
/10*)536(
_ =
+
=
Togetherwiththeinternalacquisitionandcomputationtime(1.97msformachine_nomagscenario),thetotal
timefromacquisitionofthedatauntilthereceptionatthehostis5.53ms.
Example2:Quaternionorientation dataoutputmodeplus timestampat 120Hz witha baudrate of921600
bps.
Quaternionorientationdatais16bytes,timestampis2bytes.
ms
sbits
bytebits
timeontransmissi 25.0
)/(921600
/10*)518(
_ =
+
=
Togetherwiththeinternalacquisitionandcomputationtime(1.97msformachine_nomagscenario),thetotal
timefromacquisitionofthedatauntilthereceptionatthehostis2.22ms.